T-2000CK-200H 2hp Cyclone ExtractorCode 508338AT&M: 26/03/2015REF: 508500
Assembly104. Locate the two long and short cross support brackets (4-5). Line up the pre-drilled holes in one of the crosssupport brackets with the pr
Assembly117. Locate the extraction funnel (12). Loosen the clamping rig bolt/nut to the base of the funnel, lower the wide end of the funnel on top of
Assembly12You will require the bin (9), bin castor wheels (22), binlever clamps with Phillips screws and nuts (25), bin handle (20), 1/4” domed nuts (
Assembly1312. Locate the bin handle (20), button Phillips screws (f) and domed head nuts (b). Line up the threaded holes in the handle (20) with the
Assembly14 16. Locate the air fi lter cartridge (14) and six 5/16" Hex bolts (h), with assistance position the fi lter cartridge under the
Assembly15d20. Find the shaker paddle operating handle (15) andM6 x12mm bolt (c). Insert the handle’s drive socket onto the shaker paddle’s drive shaf
Assembly1623. Locate the manometer (17), manometer hose (18)and the two small clips (24). From the opposite side of the extractor insert the hose (18
Machine Footprint171,000mm1,250mm1,800mm
Illustration and Parts Description1815111217B1443212319209221012137A25
Illustration and Parts Description19NVR Switch assemblyGreen (ON) Emergency Stop (Red)ManometerVacuum Gauge indicator to monitor the air fl ow in the d
Index of Contents2Declaration of ConformityCopied from CE Certifi cateThe undersigned, George N. SifoniosAuthorised by META INTERNATIONAL CO., LTDNO.
Illustration and Parts Description208182424
Illustration and Parts Description21Pull up the bin lever clamphandles to release binPull the bin out to empty the contentsRotate the shaker paddle op
Operating Instructions22Levelling the ExtractorIf you fi nd the extractor castors (21), are not in contact with the fl oor you can adjust them by loosen
Operating Instruction and Ducting System23Fig 63Fig 64-65-66If the reading has decreased, check the following:•Check the hoses are secure, ‘NOT LOOSE’
Maintenance24WARNING! BEFORE CARRYING OUT ANY MAINTENANCE DISCONNECT THE CYCLONE EXTRACTOR FROM THE MAINS SUPPLYWARNING! KEEP CHILDREN AWAY FROM WORK
Weekly LEV System Maintenance Log25Week DateChecked by Check all ducting for physical damageCheck inlets, clear any obstructions if foundCheck o
Weekly LEV System Maintenance Log26Week DateChecked by Check all ducting for physical damageCheck inlets, clear any obstructions if foundCheck o
LEV Testing27Why should I bother with LEV? The law says you must control the risks from these sub-stances (the Control of Substances Hazardous to Heal
Exploded Diagram/Parts List28
Exploded Diagram/Parts List29NO Description Q’TY1 Motor 12 Main Housing 13 Aluminum Impeller 14 Round Collector 15 Reducing Collector 16 Upper Leg 4
What’s Included3Quantity Item Part Model Number1 No T-2000CK-200H Cyclone Extractor1 No Motor Assembly 14 No Upper Leg Square Tubes 24 No
Wiring Diagram30Single Phase Teminal Jumper Power Sourse
Notes31
Axminster Tools & Machinery LtdWeycroft Avenue, Axminster, Devon EX13 5PHaxminster.co.ukPlease dispose of packaging for the product in a responsib
What’s Included44657 89 10
What’s Included511 121314191615171820
What’s Included621222325242627a b c d e f g h
General Safety Instructions for 230V Machines7 These machines are supplied with a moulded 16 Amp plug and 3 core power cable. Before using the machine
General Safety Instructions for 230V Machines8If the particle fi lter starts to clog, this reduces the air fl ow and hence the machine becomes less effi
Assembly9Having unpacked the boxes, put all components where they are readily to hand. Locate the motor assembly (1), the upper and lower leg square t